If you get an error that the egs002.dll is missing, ensure the model file is placed in the MODELS directory, not just the LIBRARY directory.
Place a low-value shunt resistor (e.g., 0.1 Ohm ) between the bottom source terminals of your H-bridge and the ground. Connect the top node of this resistor to the IFB pin. If the current spikes and the voltage across this resistor exceeds 0.5V, the EGS002 will automatically shut down the SPWM drive outputs to simulate over-current protection.
The EG8010‘s 12MHz external crystal provides the master clock. Adjusting simulation parameters such as the LC filter cutoff frequency and the feedback divider ratios allows you to optimize the output voltage regulation and transient response before building the physical prototype.
Inductor and Capacitor to smooth the output to a pure sine wave. Load: A resistor to simulate the load ( Troubleshooting the Simulation